A tailor-made product for ship interiors
E-PREDICT has been developed for marine applications these products have been specifically developed to withstand hostile, damp and salty environments.
Securing your goods, your crews and passengers !
Over 12000 already manufactured
30% of major maritime disasters are due to on-board fires.
The costs incurred by on-board fires represent the most substantial budget for marine insurers, not to mention operating losses and downtime.
In numbers
« Fire is the 3rd leading cause of total loss. »
According to Allianz’s annual marine report
« 30% of on-board incidents are due to fire »
According to IUMI (International Union of Marine Insurance)
In 2023, 55 total losses due to fire will be reported out of just over 200 fires on board ships.
• Continuously MONITOR plant constants 24/7.
• STRENGHTENS your risk prevention plan.
• OVERSEES protected electrical equipment.
• PROTECTS your human and environmental capital.
• OPTIMIZES your preventive maintenance efforts.
• PREVENTS unpredictable interruption and minimize operating losses.
• LOWERS the risk of electrical breakdowns.
• PRESERVES your continuity of your services.
• TARGETS maintenance towards identified faults.
• ENHANCES vulnerability rates.
• MINIMIZE damage and associated financial losses.
• PROTECTS your electrical equipment.
REAL-TIME SUPERVISION OF YOUR INSTALLATIONS
Cargo, ferries, Ro-ro Pax, cruise ships, barges, extraction platforms, wind farms and the National Navy - all maritime sectors are concerned by electrical risk.
Access your secured installations anytime, anywhere.
APPREDICT provides a guided, step-by-step installation process, assuring compliance and offering you the status of your equipments protected by E-PREDICT.
Plug & Play
E-PREDICT Contact Sec
Set-up the E-PREDICT in 5 minutes, with APPREDICT
Its dry contact output allows you to connect an external alarm device, or a cut-off device for the installation to be protected ( devices not supplied)
-
CNPP Certified (Certificate N°83.24.221) certification
-
EMC CE marking according to: EN301489-17 V3.1.0, EN301489-1 V2.2.0, EN61326-1 : 2013
-
Degree of protection according to IEC 60529: Enclosure IP31
-
Design according to DFMEA method
-
End-to-end eco-design
-
Design, manufacture and raw materials comply with the UL standard (certification not yet implemented).
-
DIN rail dimensions: 6U
-
No radio communication
-
In case of alarm, gluing of dry contact: limitations 24V – 2A
-
Power supply: 110/240 V~
-
Frequency: 50/60 Hz
-
Maximum current consumption: 0.1 A
-
Operating temperature: -15°C to +68°C
-
Relative humidity: 20 – 85
-
Operating altitude: 0 – 2000 m
-
Overvoltage category: III
-
EMC according to: EN301489-17 V3.1.0, EN301489-1 V2.2.0, EN61326-1 : 2013
-
Degree of protection to IEC 60529: Enclosure IP31
-
Dimensions: 106x62x90 (WxDxH)
-
Weight: 240 g
-
3-meter cable for dry contact.
-
Can be connected to an external device (flashing beacon).
-
No display and processing of measurements and alarms in HDSN Supervision.
-
SMS alerts by adding a transmitter (not supplied).
E-PREDICT located at the top centre of the protected equipment.
Integrated algorithm with verification loop and alarm triggering every 30 seconds.
Each time the E-PREDICT is powered up, it learns the environment again. Time for optimum operating conditions: 8 hours and 30 minutes.
Internal self-diagnosis every 30 seconds: checks operation of gas, microparticle, temperature and humidity sensors, fan (V2 only) and microcontroller.
Smartphone application for installing and configuring E-PREDICT.
Installation recommendation: to ensure optimum system operation, please carry out a thermographic check of the protected equipment during the learning phase (8.30 hours after power-up).