Prevent the occurrence of electrical fires

Over 12000    already manufactured

• Continuously MONITOR plant constants 24/7.

STRENGHTENS  your risk prevention plan.

OVERSEES  protected electrical equipment.

PROTECTS your human and environmental capital.

OPTIMIZES your preventive maintenance efforts.

PREVENTS unpredictable interruption and minimize operating losses.

E-Predict HDSN

LOWERS the risk of electrical breakdowns.

PRESERVES your continuity of your services.

TARGETS maintenance towards identified faults.

ENHANCES vulnerability rates.

MINIMIZE  damage and associated financial losses.

PROTECTS your electrical equipment.

Real time protection for your installations

The dry contact is universal, providing you with complete control over the solution for seamless integration into your management electronics such as BMS, PLC, sound or flash HMI devices, and more. You have a real-time access to the constants of your installations. No cloud, no radio – all the data belongs solely to you.

Access your secured installations anytime, anywhere.

APPREDICT provides a guided, step-by-step installation process, assuring compliance and offering you the status of your equipments protected by E-PREDICT.

Plug & Play

E-PREDICT Contact Sec

Set-up the E-PREDICT in 5 minutes, with APPREDICT

Its dry contact output allows you to connect an external alarm device, or a cut-off device for the installation to be protected ( devices not supplied)


QuoteTechnical data
  • CNPP Certified (Certificate N°83.24.221) certification

  • EMC CE marking according to: EN301489-17 V3.1.0, EN301489-1 V2.2.0, EN61326-1 : 2013

  • Degree of protection according to IEC 60529: Enclosure IP31

  • Design according to DFMEA method

  • End-to-end eco-design

  • Design, manufacture and raw materials comply with the UL standard (certification not yet implemented).

  • DIN rail dimensions: 6U

  • No radio communication

  • In case of alarm, gluing of dry contact: limitations 24V – 2A

  • Power supply: 110/240 V~

  • Frequency: 50/60 Hz

  • Maximum current consumption: 0.1 A

  • Operating temperature: -15°C to +68°C

  • Relative humidity: 20 – 85

  • Operating altitude: 0 – 2000 m

  • Overvoltage category: III

  • EMC according to: EN301489-17 V3.1.0, EN301489-1 V2.2.0, EN61326-1 : 2013

  • Degree of protection to IEC 60529: Enclosure IP31

  • Dimensions: 106x62x90 (WxDxH)

  • Weight: 240 g

  • 3-meter cable for dry contact.

  • Can be connected to an external device (flashing beacon).

  • No display and processing of measurements and alarms in HDSN Supervision.

  • SMS alerts by adding a transmitter (not supplied).

E-PREDICT located at the top centre of the protected equipment.

Integrated algorithm with verification loop and alarm triggering every 30 seconds.

Each time the E-PREDICT is powered up, it learns the environment again. Time for optimum operating conditions: 8 hours and 30 minutes.

Internal self-diagnosis every 30 seconds: checks operation of gas, microparticle, temperature and humidity sensors, fan (V2 only) and microcontroller.

Smartphone application for installing and configuring E-PREDICT.

Installation recommendation: to ensure optimum system operation, please carry out a thermographic check of the protected equipment during the learning phase (8.30 hours after power-up).